Common Troubleshooting
Problem: Fading or Inconsistent Mark Quality
Most likely cause: Dirty protective window or F-theta lens.
Fix: Clean both optics following the procedure above. If quality doesn’t improve, check:
- Focus distance (may have shifted)
- Laser power output (use a power meter if available)
- Material surface (different batch = different results)
Problem: Marks Are Blurry or Have Soft Edges
Most likely cause: Focus issue or optical contamination.
Fix:
Problem: Laser Won’t Fire or Intermittent Firing
Most likely cause: Electrical connection issue or safety interlock triggered.
Fix:
Problem: Overheating Alarm
Most likely cause: Cooling system failure or obstruction.
Fix:
Problem: Galvo Scanner Noise or Vibration
Most likely cause: Contamination or wear in the galvo assembly.
Fix: This requires professional service. Do not attempt to disassemble the galvo scanner yourself. Contact the manufacturer or a certified service technician. Operating a malfunctioning galvo can cause permanent damage.
When to call professional service:
- Power output has dropped more than 20% despite clean optics and proper cooling
- Mark quality is inconsistent despite correct settings and focus
- The laser source shows fault codes that don’t clear after power cycling
- You hear unusual noises from the laser source or galvo
- Any visible damage to the fiber cable, optics, or electrical components